Finding Roof Leaks

Roof leaks are a significant headache to fix. The very good news is that some leaks are predictable – especially as the roof ages. By identifying areas that are prone to creating problems, methods can be taken that will avoid roof problems cost efficiently.

Visit for more information: nyt tag.

Appear For Roof Leaks Near Penetrations Flashings and sealants at penetrations via the roof membrane are frequent problems spots. Normally in single-ply roofing systems, penetration flashings are the same material as the roof membrane and are bonded to the field membrane. Inspect the laps, seams and sealants at these areas often. Factory-assembled boots can address field installation issues at penetrations. It is vital that technicians effectively seal the boot to the field membrane, exactly where issues commonly take place. Roof drains that penetrate a roof membrane can be specifically troublesome for the reason that rain that falls onto the roof sooner or later flows over the drain’s seal. Drains ought to be large sufficient to deal with heavy rainfalls, and they must have a screen that stops debris from flowing down the pipe. Workers must clean the drain regularly to avoid blockage of the screen and set up recessed drain sumps. A positive slope in the roof also can avoid ponding around drains. The most effective way to keep away from leaks at roof penetrations is to stay clear of penetrations altogether. For instance, ducts, conduits and other piping that runs horizontally across the roof often are placed on strong supports that are anchored to and penetrate the roof membrane at regular intervals.

To stay clear of these penetrations, managers can specify solutions with adjustable heights and soft feet that rest on the membrane. If a horizontal element need to be anchored to the roof, build a curb and secure the element supports to the curb. Roof Leaks On The Perimeter Leaks occur near roof edges because of the transition from versatile membrane flashings to inflexible sheet-metal flashings. Technicians should really guarantee that sheet-metal laps shed water, and they should inspect the sealants at these locations routinely. Pre-manufactured sheet-metal roof accessories can solve lots of roof-perimeter problems. Managers can specify custom-produced accessories for copings at parapet walls and reglets at masonry or interior increasing walls. These elements ordinarily snap with each other, and technicians can dismantle and re-install them in the course of roof-membrane replacements. Water issues also happen close to expansion joints at roof perimeters. To address places exactly where constructing expansions and contractions are likely to take place, managers might want to to contemplate specifying pre-manufactured roof accessories. But managers need to make confident accessories they specify are compatible with the roof membrane. Condensation And Roof Leaks In some cases, a roof may seem to leak in January when the temperature dips beneath freezing, but the roof may well not be leaking. What occurs is condensation is made when the warm, moist interior air inside the building contacts cold surfaces or when cold air leaks by way of the building’s exterior skin. This dilemma could possibly result from a missing or inadequate air barrier or vapor retarder on ceilings or walls, or from inadequate insulation or ventilation. Cold regions above the insulation in joist cavities or attic spaces must be vented. If all-natural ventilation is tough or too expensive, technicians can install a fan that moves moist air out of the cold space.

DEWALT DWFP12658

In order to take your roof to a whole new level, you will need to buy the right tools.

The DEWALT DWFP12658 has been made to generate your shingles shine at all times, and that´s what you should see today. And that means you should please read on to find out more regarding the DEWALT DWFP12658.

Read more here: DEWALT DWFP12658

“Compact Body Design”
The DEWALT DWFP12658 provides you with better control and balance that you’ve been surfing for, because its body has been designed just for that. This roofing nailer will place any shingle accurately as a result of its adjustable shingle guide. Furthermore, you will be able to alter between contact and sequential mode very easily due to a selectable trigger. Your shingles won’t become damaged the use of the DEWALT DWFP12658 simply because this machine includes a special tool that prevents this from happening.

Control and Safety
The DEWALT DWFP12658 also incorporates tool protection and safety due to its skid-resistant wear guards/pads. Addititionally there is an over-molded grip that will provide you with the control luxurious that you have been seeking. The DEWALT DWFP12658 can be considered as the top coil nailers around, and that´s not an exaggeration in any way. This tool includes a lightweight and engaging package that you will adore straight away. Speed and safety were important objectives for the teams that built the DEWALT DWFP12658, and you may realize this fact right away. Now there is no need to rent a gun, as the DEWALT DWFP12658 is often a cheap tool.

Pros
-The DEWALT DWFP12658 is extremely easy to adjust and load, so you’ll make a great investment if you decide on this machine.-It’s many precautionary features that will assist you to avoid shooting yourself, so you will avoid many unexpected misfires.-It is a reliable roofing gun.-The machine is well balance and nice.

Cons
-You will discover that this DEWALT DWFP12658 has some quirks. For example, the DEWALT DWFP12658´s adjustable shingle guide will usually move and wiggle loose.-You might have to adjust the equipment every once in awhile.

We now have talked about the DEWALT DWFP12658 and the amazing things this machine can perform for you personally today. The DEWALT DWFP12658 features a compact body design that provides you with the control and balance which you have been searching for. In addition, the DEWALT DWFP12658 is incredibly an easy task to adjust and contains a lot of security features.

NYT TAG

tagtyperChoosing the correct replacement for an aged roof – or identifying the best choice for a new building – is no easy task. The perfect roofing solution for one building may be the worst option for another just down the street. That’s because no two buildings are precisely alike, even if they closely resemble each other.

So how do you choose a new roof, given all the choices in the marketplace? You can start by asking a series of questions, before you choose the roof, the roofing contractor or the manufacturer.

Need to know more, visit nyt tag

1. What is this building’s mission statement?

Before calls are made to roofing contractors or manufacturers, the first item to address is the company’s mission statement as it relates to the building.

Whether you are building new facilities or managing existing properties, you want to be confident that the roofing systems you select deliver the performance you expect. More often than not, the building itself dictates the appropriate roofing system specification.

You need to know as much about the building and its future as possible. Does the company plan to keep this building as part of its real estate assets for the next 10 to 20 years? Are there any plans to expand it in the near future, or to change its use? What are its current and future occupancy, insulation requirements, aesthetic priorities and even the maintenance schedules for rooftop equipment?

These and other mission statement issues will help shape answers to types of roofing to consider and how much of the capital budget is really needed for the job.

Start your questions with what is the building going to be used for. If it’s a spec building, maybe you only need a basic roof. But, if the facility has a special use, such as an airline reservation center with computers in it, then your considerations for roofing options are quite different.

For example, as more companies move toward operating 24 hours daily, seven days a week to satisfy global customers, the data center must never spring a rooftop leak. Water on computer systems generally spells disaster.

A special set of concerns arise for cooling-dominated climates. Does the roof contribute to air conditioning savings and address other key issues? Is it part of a total energy program? There is a growing concern about urban heat islands. Reflective, white roofs have become of interest in those areas for a few reasons. They keep the building cooler, reduce air conditioning costs and also minimize the heat-loading of the surrounding environment.

 

2. What physical and other elements influence the roofing system selection?

After identifying the goals and mission of a facility, it’s time to evaluate the building itself. You need to begin by looking at the building’s location and the attributes of its surrounding area. You need to examine building codes, weather trends, topography – even the direction the building faces.

The physical characteristics of the building are also crucial: size, shape, design, height and age.
You also need to look at the construction materials used to build the facility and the location of HVAC and fire protection equipment, particularly if either or both of these are partially or totally housed on the rooftop.

When it comes to roof replacement, you need to list the attributes of the roof area itself. It’s best to detail the roof’s size, shape, slope, deck construction, edge detailing, protrusions, rooftop access and existing roofing system. Along with this basic information, you need to find out why the original roof is no longer adequate.

3. What flexible-membrane roofing options are available?

SPRI, the association that represents sheet membrane and component suppliers to the commercial roofing industry, identifies three major categories of membranes: thermosets, thermoplastics and modified bitumens.

Thermoset membranes are made from rubber polymers. The most common is EPDM, often referred to as “rubber roofing.” These membranes are well suited to withstand the potentially damaging effects of sunlight and the common chemicals found on roofs. They are easily identified on the rooftop. Just look at the seams. Thermoset membranes require liquid or tape adhesives to form a watertight seal at the overlaps.
Thermoplastic membranes are based on plastic polymers. The most common is PVC, which is made flexible by adding plasticizers. Thermoplastic membranes have seams that are most commonly formed using heat welding. Most thermoplastic membranes are manufactured with a reinforcement layer, usually polyester or fiberglass to provide increased strength and dimensional stability.

Hypalon thermoplastic begins as a thermoplastic, but cures over time to become a thermoset. Like other thermoplastics, Hypalon materials are heat sealed at the seams.

Another thermoplastic hybrid is thermoplastic polyolefin (TPO), which combines the attributes of EPDM and PVC. TPO membranes do not cure after exposure to the elements and remain hot-air weldable throughout their service life. Most TPO membranes are reinforced with polyester, fiberglass or a combination of the two, but unreinforced TPO membranes are available.

Modified bitumen membranes incorporate the formulation and prefabrication advantages of flexible-membrane roofing with some of the traditional installation techniques used in built-up roofing. Modified bitumen sheets are factory-fabricated, composed of asphalt which is modified with a rubber or plastic polymer for increased flexibility, and combined with a reinforcement for added strength and stability.

4. Which type of membrane and attachment system are best for the building?

Many factors determine the best system for a particular building. For most buildings, there are a number of options and advantages that need to be weighed against the facility’s mission statement. The decision should not be made only on the basis of cost. Other important considerations for membranes are building height, wind exposure, anticipated roof traffic and aesthetics.

The attachment system also depends on the specific building’s characteristics. If the roof deck is able to withstand the weight, a ballasted roof may be the best option. But, if the slope of the roof is greater than 2 inches every foot, this system may not be appropriate. There are other limitations to ballasted systems, such as roof height, proximity to shorelines and other high wind zones, and the availability of ballast.
A steel or wood deck that easily accepts fasteners makes a good substrate for a mechanically fastened membrane. These systems can be designed to provide the necessary resistance to known wind forces and are not subject to slope limitations.

Another alternative is the fully adhered system, in which the membrane is attached to the prepared substrate using a specified adhesive. Depending on the membrane, the adhesive may be solvent- or water-based or asphalt. The finished surface of an adhered roof is smooth.

For those concerned with building aesthetics, colored membranes can make an attractive contribution to the building’s appearance.

5. Does all roofing material delivered to the job site bear the UL label?

If not, specify that it must. This is the only way you can guarantee that the roofing materials installed on your roof are the same materials tested by Underwriter’s Laboratories. Additionally, be sure that the roof assembly you buy or specify, which includes the insulation, is UL-classified and -labeled. Using an insulation other than what was tested with the roofing membrane may void the UL classification. If the UL Building Materials Directory does not list the roofing system you are sold, insist on verification of the classification in the form of a photocopy of the UL’s letter of approval.